• DocumentCode
    1360532
  • Title

    Partial discharge influence on dissipation factor values during stator-bar testing

  • Author

    Contin, Alfredo ; Zhu, Hugh

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Univ. of Trieste, Trieste, Italy
  • Volume
    27
  • Issue
    6
  • fYear
    2011
  • Firstpage
    8
  • Lastpage
    14
  • Abstract
    The article investigates how partial discharge activity can influence dissipation factor values in stator-bar testing. In this study, the PD phenomenon was simulated as a process composed of periodic positive and negative bursts of PD pulses over a period T of the applied voltage (frequency = 50 Hz, T 20 ms in this work). These periodic pulses generate a frequency spectrum whose fundamental frequency (50 Hz) can interfere with DF values while DF values are measured at the same frequency. An artificial defect was made on a virgin stator bar to generate PD signals. Both the simulated and real PD signals recorded from the bar at various voltage levels were studied, and the parameters of PD signals that influence the DF values were investigated.
  • Keywords
    electric machines; machine testing; partial discharge measurement; stators; DF values; PD activity; PD pulses; PD signals; dissipation factor measurements; dissipation factor values; frequency 50 Hz; frequency spectrum; negative bursts; partial discharge activity; partial discharge measurements; periodic positive bursts; stator-bar testing; time 20 ms; Dissipation factors; Frequency measurement; Mathematical model; Partial discharges; Stator windings; dissipation factor; insulation system; partial discharge; stator bar;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0883-7554
  • Type

    jour

  • DOI
    10.1109/MEI.2011.6059979
  • Filename
    6059979