DocumentCode
1362678
Title
Open-Circuit Fault Diagnosis and Fault-Tolerant Strategies for Full-Bridge DC–DC Converters
Author
Pei, Xuejun ; Nie, Songsong ; Chen, Yu ; Kang, Yong
Author_Institution
State Key Lab. of Adv. Electromagn. Eng. & Technol., Huazhong Univ. of Sci. & Technol., Wuhan, China
Volume
27
Issue
5
fYear
2012
fDate
5/1/2012 12:00:00 AM
Firstpage
2550
Lastpage
2565
Abstract
This paper proposes a four-step open-circuit fault diagnosis and fault-tolerant scheme for isolated phase-shifted full-bridge (PSFB) dc-dc converters to improve the reliability. The fault diagnostic method utilizes the primary voltage of the transformer as the diagnostic criterion, which can be obtained easily by adding an auxiliary winding. When an open-circuit fault occurs in any switch of the PSFB converter, the proposed fault detection method can generate an indication of the abnormal state and trigger an active-phase-shifted in the control system. Under the APS state, it is very easy to locate the exact position of faulty switch because the voltage waveform of the primary winding heavily depends on the location of the faulty switch. After locating the position of the faulty switch, the PSFB converter is reconfigured into an asymmetrical half-bridge (AHB) converter by turning ON the normal switch in the faulty leg and adding a redundant winding to the secondary side. Therefore, the rebuilt AHB converter can keep the output voltage constant under a reduced power rating after the open-circuit fault. The operational principle, design consideration, and implementation are discussed in this paper. The experimental results are given to verify the validity of theoretical analysis. The proposed strategies outperform the traditional schemes in terms of cost, reliability, and power density.
Keywords
DC-DC power convertors; fault diagnosis; fault tolerance; reliability; transformer windings; transformers; AHB converter; APS; active-phase-shifted control system; asymmetrical half-bridge converter; auxiliary winding; fault detection method; fault-tolerant strategy; four-step open-circuit fault diagnosis; isolated PSFB DC-DC converter; isolated phase-shifted full-bridge DC-DC converter; power rating reduction; transformer primary voltage; voltage waveform; Circuit faults; Digital signal processing; Fault diagnosis; Fault tolerance; Fault tolerant systems; Switches; Windings; Active-phase-shifted (APS); fault diagnosis; fault-tolerant; open circuit; reliability;
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/TPEL.2011.2173589
Filename
6061967
Link To Document