• DocumentCode
    1378054
  • Title

    A method of designing small power transformers for communication equipment

  • Author

    Sear, Hubert S.

  • Author_Institution
    Waltham, Mass.
  • Volume
    75
  • Issue
    6
  • fYear
    1957
  • Firstpage
    758
  • Lastpage
    761
  • Abstract
    A SIMPLE METHOD is presented for the design of a power transformer which does not require any trial-and error-calculations. Optimum wire gauges for each winding to minimize losses, and optimum cores made of commercially available laminations, can be easily obtained. The method is suitable for power transformers operating at any frequency where stray capacitative and inductive effects are negligible, having one or more secondary windings, and rated up to 500 volt-amperes.
  • Keywords
    Capacitance; Insulation; Lamination; Power transformers; Transformer cores; Windings; Wires;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1957.6372588
  • Filename
    6372588