DocumentCode
1378915
Title
Forward current surge failure in semiconductor rectifiers
Author
Gentry, F. E.
Author_Institution
General Electric Company, Clyde, N. Y.
Volume
77
Issue
5
fYear
1958
Firstpage
746
Lastpage
750
Abstract
The application of semiconductor rectifiers to most practical circuits requires a knowledge of the device´s ability to withstand the forward current surges encountered as a result of severe faults or high instantaneous overloads. In particular, an understanding of the nature of failure is desirable in order to properly protect the rectifier. Suitable fuses can then be chosen to obtain optimum utilization of the rectifier. Gutzwiller1 has developed fuse-selection techniques which are adequate for this purpose.
Keywords
Heating; Junctions; Mathematical model; Rectifiers; Silicon; Surges;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1958.6372718
Filename
6372718
Link To Document