DocumentCode
1380571
Title
15-term self-calibration methods for the error-correction of on-wafer measurements
Author
Heuermann, Holger ; Schiek, Burkhard
Author_Institution
Rosenberger Hochfrequenztech., Tittmoning, Germany
Volume
46
Issue
5
fYear
1997
fDate
10/1/1997 12:00:00 AM
Firstpage
1105
Lastpage
1110
Abstract
An improved method of network analyzer calibration is described using the 15-term full model which includes all leakage errors between on-wafer probe tips. This model is well suited to eliminate measurement errors of network analyzer measurements on the wafer. All procedures presented are so-called self-calibration methods, allowing for standards that are not completely known. This allows one to create calibration standards in an easy way and to monitor the calibration process. Simple and robust closed-form equations are presented for all procedures. All procedures can be derived from the general method MURN (match, unknown, reflect, network). The MORN (match, open, reflect, network) is presented, which is particular interesting for on-wafer-measurements. Furthermore, the TMRN (through, match, reflect, network) procedure presented is especially designed for coaxial measurement problems. Experimental results of the TMRN method attest to the very good accuracy and viability of the 15-term self-calibration procedures and can be compared with other 15-term procedures
Keywords
S-parameters; calibration; measurement errors; microwave measurement; network analysers; MORN; MURN; TMRN; closed-form equations; coaxial measurement problems; leakage errors; measurement errors; network analyzer calibration; on-wafer measurements; self-calibration methods; Calibration; Coaxial components; Error analysis; Error correction; Measurement errors; Measurement standards; Probes; Scattering parameters; Semiconductor device modeling; Testing;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.676721
Filename
676721
Link To Document