Abstract
In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component id in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically, in the case of stator and rotor faults, the id spectrum components at frequencies 2f and 2sf, respectively, are quite independent of control parameters and dependent on the fault extent
Keywords
closed loop systems; control system analysis; fault diagnosis; induction motors; machine testing; machine theory; machine vector control; rotors; stators; closed-loop control impact; diagnostic indexes; diagnostic procedure; field current component spectrum; field-oriented control; induction motors faults diagnosis; rotor faults; stator faults; Associate members; Circuit faults; Electrical fault detection; Fault diagnosis; Frequency; Induction machines; Induction motors; Open loop systems; Rotors; Stators;