• DocumentCode
    1388899
  • Title

    A GSO depth of interaction detector for PET

  • Author

    Yamamoto, S. ; Ishibashi, H.

  • Author_Institution
    Kobe City Coll. of Technol., Japan
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    6/1/1998 12:00:00 AM
  • Firstpage
    1078
  • Lastpage
    1082
  • Abstract
    The authors have developed a GSO depth of interaction detector. Three GSO scintillators with different concentration of Ce were chosen and stacked along depth of interaction direction and optically coupled to a photomultiplier tube (PMT) or a position sensitive photomultiplier tube (PSPMT). Pulse shape, light output and zero-cross time were measured to select a proper combination of GSO scintillators with different concentration of Ce. Selecting 3 GSO scintillators with different concentration of Ce, a single stacked GSO/PMT depth of interaction detector was fabricated for estimating the possibility of this method. Using the zero-cross time analysis, 3 peaks correspond to decay times of the 3 GSO scintillators were obtained. Finally, a GSO/PSPMT depth of interaction block detector was fabricated and tested. The block detector consists of 7×7 matrix of GSO scintillators which have 3 layers of different concentration of Ce optically coupled to PSPMT. The pulse shape analysis was used for determination of depth of interaction direction while the Anger logic was used for transaxial and axial directions. Good separation was observed in depth of interaction direction as well as transaxial and axial directions. These results indicate that the GSO block detector may become one solution to develop a positron emission tomograph (PET) with depth of interaction detection capability
  • Keywords
    biomedical equipment; positron emission tomography; solid scintillation detectors; Ce; Ce concentration; GSO depth of interaction detector; GSO scintillators; PET; axial direction; depth of interaction block detector; light output; medical diagnostic imaging; medical instrumentation; position sensitive photomultiplier tube; pulse shape; transaxial direction; zero-cross time; Detectors; Optical coupling; Optical pulse shaping; Optical sensors; Photomultipliers; Positron emission tomography; Pulse measurements; Shape measurement; Testing; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.681982
  • Filename
    681982