DocumentCode
1404761
Title
Limits of accuracy in resistance measurement
Author
Miller, C.H.
Author_Institution
University of New South Wales, School of Electrical Engineering, Sydney, Australia
Volume
109
Issue
16
fYear
1962
fDate
9/1/1962 12:00:00 AM
Firstpage
299
Lastpage
306
Abstract
The resolution that can be achieved in resistance measurement is shown to be limited by the amplitude of thermal noise relative to the input power of the resistance. The errors of measurement due to resolution and power loading are analysed and the minimum value of their sum is found to be proportional to the cube root of the circuit and detector noise factors, the detector bandwidth and the loadcorrection error. The noise factors of some common circuit arrangements are evaluated and the other errors of measurement in addition to resolution and power-loading errors are discussed. The total error is shown to have a limiting value near 1 part in 108 for existing high-quality standard resistors and this is illustrated by a practical example.
Keywords
electric resistance measurement; noise;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part C: Monographs
Publisher
iet
ISSN
0369-8904
Type
jour
DOI
10.1049/pi-c.1962.0044
Filename
5245389
Link To Document