• DocumentCode
    1405237
  • Title

    Improved control strategy on buck-type PFC converter

  • Author

    Hirachi, K. ; Nakaoka, M.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Yamaguchi Univ., Japan
  • Volume
    34
  • Issue
    12
  • fYear
    1998
  • fDate
    6/11/1998 12:00:00 AM
  • Firstpage
    1162
  • Lastpage
    1163
  • Abstract
    In general, a single phase buck-type power factor correction (PFC) converter has a significant problem of the increase in volumetric size and weight, because this type of converter has to employ a smoothing inductor designed for high inductance to reduce the harmonic components included in the line input current. A new control strategy is proposed for a buck-type PFC converter which can greatly reduce the size and weight of its smoothing inductor
  • Keywords
    PWM power convertors; harmonic distortion; harmonics; inductance; power factor correction; buck-type PFC converter; control strategy; harmonic components reduction; line input current; power factor correction converter; smoothing inductor size reduction;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19980901
  • Filename
    702343