• DocumentCode
    1409816
  • Title

    Method of rapidly reversing large currents in highly inductive loads

  • Author

    Barney, G.C.

  • Author_Institution
    University of Birmingham, Department of Physics, Birmingham, UK
  • Volume
    113
  • Issue
    12
  • fYear
    1966
  • fDate
    12/1/1966 12:00:00 AM
  • Firstpage
    2031
  • Lastpage
    2034
  • Abstract
    The paper describes a method of rapidly reversing a large current in a highly inductive load, which has been satisfactorily applied to the paralleled field windings of a pair of 2MW d.c. generators. The technique discussed avoids disconnection of the inductive load whilst current is still flowing, and hence the problem of dissipating the stored energy. The power unit evolved consists of two 3-phase fully controlled thyristor bridges arranged in a figure-of-eight formation. The means of avoiding large circulating currents by controlled methods is discussed in detail.
  • Keywords
    DC generators; load (electric); switching;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1966.0353
  • Filename