DocumentCode
1409816
Title
Method of rapidly reversing large currents in highly inductive loads
Author
Barney, G.C.
Author_Institution
University of Birmingham, Department of Physics, Birmingham, UK
Volume
113
Issue
12
fYear
1966
fDate
12/1/1966 12:00:00 AM
Firstpage
2031
Lastpage
2034
Abstract
The paper describes a method of rapidly reversing a large current in a highly inductive load, which has been satisfactorily applied to the paralleled field windings of a pair of 2MW d.c. generators. The technique discussed avoids disconnection of the inductive load whilst current is still flowing, and hence the problem of dissipating the stored energy. The power unit evolved consists of two 3-phase fully controlled thyristor bridges arranged in a figure-of-eight formation. The means of avoiding large circulating currents by controlled methods is discussed in detail.
Keywords
DC generators; load (electric); switching;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1966.0353
Filename
5247365
Link To Document