• DocumentCode
    1413892
  • Title

    Region of Interest Reconstruction in X-Ray Fluorescence Computed Tomography for Negligible Attenuation

  • Author

    La Riviere, Patrick ; Vargas, Phillip ; Xia, Dan ; Pan, Xiaochuan

  • Author_Institution
    Dept. of Radiol., Univ. of Chicago, Chicago, IL, USA
  • Volume
    57
  • Issue
    1
  • fYear
    2010
  • Firstpage
    234
  • Lastpage
    241
  • Abstract
    X-ray fluorescence computed tomography (XFCT) is a synchrotron-based imaging modality employed for mapping the distribution of elements within slices or volumes of intact specimens. A pencil beam of external radiation is used to stimulate emission of characteristic X-rays from within a sample, which is scanned and rotated through the pencil beam in a first-generation tomographic geometry. One limitation of XFCT is the long image acquisition time required to acquire a complete set of line integrals one-by-one. Typically, even if only a portion of a slice through the object is of interest, measurement lines are acquired spanning the entire object at every projection view over 180 degrees to avoid reconstructing images with so-called truncation artifacts. In this paper, we show that when attenuation is negligible, recent developments in tomographic reconstruction theory can be used to reduce the scanning effort required to reconstruct regions of interest within the slice. The new theory provides explicit guidance as to which line integrals must be measured for a given ROI and also provides a backprojection-filtration reconstruction algorithm that averts the truncation artifacts that typically plague filtered backprojection reconstructions from truncated data. This is demonstrated through simulation studies and with real synchrotron-based XFCT data.
  • Keywords
    X-ray emission spectra; computerised tomography; filtering theory; fluorescence; image reconstruction; medical image processing; ROI; X-ray fluorescence computed tomography; backprojection-filtration reconstruction algorithm; characteristic X-ray emission; element distribution; region of interest reconstruction; synchrotron-based imaging; truncation artifacts; Attenuation; Computed tomography; Fluorescence; Focusing; Geologic measurements; Image reconstruction; Optical imaging; X-ray detection; X-ray detectors; X-ray imaging; Image reconstruction; X-ray fluorescence computed tomography; region-of-interest reconstruction;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2009.2031177
  • Filename
    5409997