• DocumentCode
    1422325
  • Title

    Error analysis of an optical current transducer operating with a digital signal processing system

  • Author

    Niewczas, Pawel ; Cruden, Andrew ; Michie, W. Craig ; Madden, W. Iain ; Mcdonald, James R

  • Author_Institution
    Strathclyde Univ., Glasgow, UK
  • Volume
    49
  • Issue
    6
  • fYear
    2000
  • fDate
    12/1/2000 12:00:00 AM
  • Firstpage
    1254
  • Lastpage
    1259
  • Abstract
    This paper analyzes errors associated with the analog-to-digital (A/D) conversion process of a digital signal processing unit (DSP) within the operation of an optical current transducer (OCT). Quantization of the analog current measurement signal leads to measurement errors which are a direct consequence of the uncertainty with which an N-bit resolution A/D assigns a binary word for a given analog input value. This paper presents comprehensive simulations of the performance of different current sensors monitored by the DSP unit and discusses aspects of compatibility between the sensor dynamic range and the resolution of an A/D conversion process. Recommendations are given on how to match the OCT to the given A/D parameters, and vice versa, in order to meet specified accuracy requirements
  • Keywords
    analogue-digital conversion; electric current measurement; magneto-optical sensors; measurement errors; A/D conversion process; accuracy requirements; analog current measurement signal; binary word; current sensors; digital signal processing system; measurement errors; optical current transducer; sensor dynamic range; Current measurement; Digital signal processing; Error analysis; Measurement errors; Optical sensors; Optical signal processing; Quantization; Signal analysis; Signal resolution; Transducers;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.893265
  • Filename
    893265