• DocumentCode
    1423351
  • Title

    A New Start-Up Demonstration Test

  • Author

    Gera, Amos Eliahu

  • Author_Institution
    Quality Manage. Div., ELTA Syst. Ltd., Ashdod, Israel
  • Volume
    59
  • Issue
    1
  • fYear
    2010
  • fDate
    3/1/2010 12:00:00 AM
  • Firstpage
    128
  • Lastpage
    131
  • Abstract
    The commonly known consecutive successes total failures (CSTF) start-up demonstration test procedure is improved to a total successes consecutive successes total failures (TSCSTF) procedure. Accordingly, a unit under test is accepted when either a total number of successful tests, or a specified number of consecutive successes of tests are observed before a total number of failures; otherwise the unit is rejected. The waiting time until termination (the length of the set of tests) of the new procedure is evaluated. A correct choice of parameters (e.g. the number of successes required for acceptance, the total number of failures causing rejection) using the new procedure may yield a shorter waiting time than that of the relevant CSTF procedure.
  • Keywords
    Markov processes; reliability; consecutive successes total failures; equipment reliability; first order Markov dependent structure; start-up demonstration test; start-up reliability; Consecutive k-out-of-n systems; consecutive successes total failures; runs test; start-up reliability; waiting-time distribution;
  • fLanguage
    English
  • Journal_Title
    Reliability, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9529
  • Type

    jour

  • DOI
    10.1109/TR.2010.2041975
  • Filename
    5418930