• DocumentCode
    1425908
  • Title

    Use of an electrostatic wattmeter as a.c./d.c. comparator

  • Author

    Choudhury, J.K. ; Bhattacharyya, S.N.

  • Author_Institution
    Jadavpur University, Department of Electrical Engineering, Calcutta, India
  • Volume
    114
  • Issue
    8
  • fYear
    1967
  • fDate
    8/1/1967 12:00:00 AM
  • Firstpage
    1171
  • Lastpage
    1173
  • Abstract
    The paper describes a null method of using a quadrant electrometer for power measurement in an a.c. circuit. The instrument is conventionally connected in an a.c. load circuit, and the `a.c. torque¿ is counter balanced by an equal and opposite `d.c. torque¿ produced by suitably applying a steady unidirectional voltage. This type of use as an a.c./d.c. comparator gives the well known advantages of the null method over the deflectional method. A simple null method has been developed which gives a measure of the a.c. power only in terms of the reading of a d.c. voltmeter and the resistance of the quadrant shunt. Calibration of the equipment as a wattmeter is not necessary. Selected experimental results have been included to illustrate how the method can be conveniently extended to magnetic-loss measurements.
  • Keywords
    electric sensing devices; magnetic leakage; magnetic variables measurement; power measurement; wattmeters;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1967.0224
  • Filename
    5249966