• DocumentCode
    1434269
  • Title

    Parameter sensitivity and inverse Nyquist method

  • Author

    McMorran, P.D.

  • Author_Institution
    University of Manchester Institute of Science & Technology, Control Systems Centre, Manchester, UK
  • Volume
    118
  • Issue
    6
  • fYear
    1971
  • fDate
    6/1/1971 12:00:00 AM
  • Firstpage
    802
  • Lastpage
    804
  • Abstract
    The equations relating perturbations of the open-loop transfer-function matrix of a multivariable linear system to those of the closed-loop transfer-function matrix and its inverse are obtained in a new and straight-forward manner. Finite and infinitesimal changes are treated with equal facility, and the condition for feedback to improve sensitivity is adapted to the inverse Nyquist method. A simple example is presented.
  • Keywords
    Nyquist diagrams; feedback; linear systems; multivariable systems; sensitivity; closed loop system; control system design; feedback conditions; finite changes; infinitesimal changes; inverse Nyquist method; linear multivariable control system; open loop transfer function matrix; perturbations relation; sensitivity improvement;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1971.0156
  • Filename
    5251783