• DocumentCode
    1435111
  • Title

    Bridge measurement of very low dielectric loss at low temperatures

  • Author

    Nelson, R.L.

  • Author_Institution
    CEGB, Central Electricity Research Laboratories, Leatherhead, UK
  • Volume
    121
  • Issue
    7
  • fYear
    1974
  • fDate
    7/1/1974 12:00:00 AM
  • Firstpage
    764
  • Lastpage
    770
  • Abstract
    The paper describes a Schering bridge, the associated apparatus and the techniques used for the determinaticm of very small values of loss tangent at power frequency, low electric stress and liquid helium temperatures. The loss tangents of several small samples of polyethylene and polytetrafluoroethylene have been measured to be less than 10¿5radians at 4.2 K. Liquid helium was used as the loss reference. It is proposed that this method is also suitable for measuring the dielectric loss of large samples.
  • Keywords
    bridge instruments; loss-angle measurement; power cables; superconducting cables; 4.2 degrees K; Schering bridge; bridge instruments; loss angle measurement; low dielectric loss; low temperature techniques; polyethylene; polytetrafluoroethylene; superconducting cables;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1974.0178
  • Filename
    5251922