DocumentCode
1435111
Title
Bridge measurement of very low dielectric loss at low temperatures
Author
Nelson, R.L.
Author_Institution
CEGB, Central Electricity Research Laboratories, Leatherhead, UK
Volume
121
Issue
7
fYear
1974
fDate
7/1/1974 12:00:00 AM
Firstpage
764
Lastpage
770
Abstract
The paper describes a Schering bridge, the associated apparatus and the techniques used for the determinaticm of very small values of loss tangent at power frequency, low electric stress and liquid helium temperatures. The loss tangents of several small samples of polyethylene and polytetrafluoroethylene have been measured to be less than 10¿5radians at 4.2 K. Liquid helium was used as the loss reference. It is proposed that this method is also suitable for measuring the dielectric loss of large samples.
Keywords
bridge instruments; loss-angle measurement; power cables; superconducting cables; 4.2 degrees K; Schering bridge; bridge instruments; loss angle measurement; low dielectric loss; low temperature techniques; polyethylene; polytetrafluoroethylene; superconducting cables;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1974.0178
Filename
5251922
Link To Document