• DocumentCode
    1440186
  • Title

    Equilibrium-based iterative tomography technique for soft X-ray in stellarators

  • Author

    Navarro, A.P. ; Ochando, M.A. ; Weller, A.

  • Volume
    19
  • Issue
    4
  • fYear
    1991
  • fDate
    8/1/1991 12:00:00 AM
  • Firstpage
    569
  • Lastpage
    579
  • Abstract
    A method to deduce local values of plasma emissivity from chord measurements has been developed and tested using data from a 30 detector soft X-ray array in the Wendelstein 7A stellarator. This technique, based on the calculated distribution of toroidal magnetic flux as the initial guess for the plasma emissivity, uses an iterative scheme to algebraically determine the distribution of the detector signals, and solves some drawbacks of the currently available tomography techniques. This method is especially suited for stellarator devices in which plasma cross sections are markedly noncircular and change as a function of the toroidal angle
  • Keywords
    X-ray detection and measurement; plasma diagnostic techniques; stellarators; 30 detector soft X-ray array; VIIA; Wendelstein 7A stellarator; chord measurements; detector signals; distribution; equilibrium-based iterative tomography; local values; noncircular cross-section; plasma cross sections; plasma emissivity; toroidal angle; toroidal magnetic flux; Magnetic flux; Plasma devices; Plasma measurements; Plasma x-ray sources; Sensor arrays; Signal detection; Testing; Tomography; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.90321
  • Filename
    90321