• DocumentCode
    1442044
  • Title

    Results of L3 BGO calorimeter calibration using an RFQ accelerator

  • Author

    Chaturvedi, U. ; Favara, A. ; Gataullin, M. ; Gratta, G. ; Kirkby, D. ; Lu, W. ; Newman, H. ; Shvorob, A. ; Tully, C. ; Zhu, R.

  • Author_Institution
    Dept. of Phys., California Inst. of Technol., Pasadena, CA, USA
  • Volume
    47
  • Issue
    6
  • fYear
    2000
  • fDate
    12/1/2000 12:00:00 AM
  • Firstpage
    2101
  • Lastpage
    2105
  • Abstract
    A novel calibration system based on a radiofrequency-quadrupole (RFQ) accelerator has been installed in the L3 experiment. Radiative capture of 1.85 MeV protons from the RFQ accelerator in a lithium target produces a flux of 17.6 MeV photons which are used to calibrate 11000 crystals of the L3 BGO calorimeter. In this paper we present results of the RFQ run taken in November 1997. A calibration precision of 0.6% was reached in the barrel of the L3 BGO calorimeter, and 0.7% in the BGO endcaps
  • Keywords
    bismuth compounds; calibration; particle calorimetry; solid scintillation detectors; BGO endcaps; Bi4Ge3O12; L3 BGO calorimeter calibration; RFQ accelerator; calibration system; radiofrequency-quadrupole accelerator; Acceleration; Calibration; Detectors; Energy resolution; Laboratories; Magnetic flux; Magnetic shielding; Particle beams; Photonic crystals; Radio frequency;