DocumentCode
1442060
Title
Pulling loads on single- and multiple-conductor impregnated-paper lead-encased cable, solid type
Author
Bellis, A. P. S.
Author_Institution
John A. Roebling´s Sons Co., Trenton, N. J.
Volume
62
Issue
3
fYear
1943
fDate
3/1/1943 12:00:00 AM
Firstpage
138
Lastpage
147
Abstract
LACK of factual information relative to the permissible pulling loads to which solid-type impregnated-paper lead-sheath power cable might be subjected by means of woven-wire pulling grips without damage to the sheath prompted the Insulated Power Cable Engineers Association to consider the subject and resulted in the laboratory tests described in this paper.
Keywords
Cable insulation; Cable shielding; Conductors; Oil filled cables; Power cables; Strain;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1943.6435654