• DocumentCode
    1442114
  • Title

    Capacitance-based tomographic flow imaging system

  • Author

    Huang, S.M. ; Plaskowski, A.B. ; Xie, C.G. ; Beck, M.S.

  • Author_Institution
    Dept. of Instrum. & Anal. Sci., Univ. of Manchester Inst. of Sci. & Technol., UK
  • Volume
    24
  • Issue
    7
  • fYear
    1988
  • fDate
    3/31/1988 12:00:00 AM
  • Firstpage
    418
  • Lastpage
    419
  • Abstract
    An instrumentation system for obtaining cross-sectional images of two-component flows is described. It uses measurements made with capacitance electrodes mounted on the outer surface of the fluid-conveying pipe, and an image reconstruction algorithm based on backprojection. Images of static physical models simulating a stratified solids/air flow are presented
  • Keywords
    computerised picture processing; computerised tomography; flow visualisation; backprojection; capacitance electrodes; computerised picture processing; cross-sectional images; fluid-conveying pipe; image reconstruction algorithm; instrumentation system; oil/gas mixtures; oil/water mixtures; static physical models; stratified solids/air flow; tomographic flow imaging system; two-component flows;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • Filename
    5708