• DocumentCode
    1447513
  • Title

    Turnaround-Point Long-Period Fiber Gratings (TAP-LPGs) as High-Radiation-Dose Sensors

  • Author

    Kher, Sanjay ; Chaubey, Smita ; Kashyap, Raman ; Oak, Shrikant Madhusudan

  • Author_Institution
    Fiber Opt. Lab., Raja Ramanna Centre for Adv. Technol., Indore, India
  • Volume
    24
  • Issue
    9
  • fYear
    2012
  • fDate
    5/1/2012 12:00:00 AM
  • Firstpage
    742
  • Lastpage
    744
  • Abstract
    This letter reports the application of turnaround-point (TAP) long-period gratings (LPGs) for radiation dosimetry. The LPGs were realized using the laser-writing technique. After a gamma dose of 6 kGy, the TAP-LPGs show a radiation-induced shift of more than 35 nm for each of the dual resonance dips, which is the highest shift reported to date for any type of fiber gratings. These LPGs can therefore be used as radiation sensors down to doses of a few Gy with modest wavelength-resolving instrumentation. The LPGs show significant sensitivity of wavelength shifts up to 80 nm for a dose of 65 kGy. We attribute the very high radiation sensitivity to near-TAP operation and doping of Boron in the fiber. This should open up applications of LPGs to radiation dosimetry.
  • Keywords
    boron; diffraction gratings; dosimetry; fibre optic sensors; high radiation dose sensors; laser writing technique; radiation absorbed dose 6 kGy; radiation absorbed dose 65 kGy; radiation dosimetry; turnaround-point long period fiber gratings; wavelength resolving instrumentation; Fiber gratings; Fiber lasers; Optical fiber dispersion; Optical fiber sensors; Optical fibers; Sensitivity; Phase-matching curves (PMC); radiation dose; sensor; turnaround-point long-period gratings (TAP-LPGs);
  • fLanguage
    English
  • Journal_Title
    Photonics Technology Letters, IEEE
  • Publisher
    ieee
  • ISSN
    1041-1135
  • Type

    jour

  • DOI
    10.1109/LPT.2012.2187637
  • Filename
    6151807