DocumentCode
1455768
Title
Precision measurement of AC voltage below 20 Hz at IEN
Author
Pogliano, Umberto
Author_Institution
Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
Volume
46
Issue
2
fYear
1997
fDate
4/1/1997 12:00:00 AM
Firstpage
369
Lastpage
372
Abstract
A new system for ac voltage measurements at low frequencies has been built at the Istituto Elettrotecnico Nazionale (IEN). The system uses a sampling voltmeter working as an integrating analog to digital converter and software programs for data acquisition and processing. An algorithm for the reconstruction of the input voltage based on a model of the converter allows the precise evaluation of the signal parameters. Comparisons at 20 Hz and 40 Hz with measurements made using the thermal converters of the national standard have shown differences lower than a few parts in 106
Keywords
analogue-digital conversion; data acquisition; measurement standards; voltage measurement; voltmeters; 20 Hz; 40 Hz; AC voltage; IEN; Istituto Elettrotecnico Nazionale; data acquisition; input voltage reconstruction; integrating analog to digital converter; precision measurement; sampling voltmeter; signal parameters; Analog-digital conversion; Calibration; Force measurement; Frequency conversion; Frequency measurement; Sampling methods; Signal sampling; Thermal force; Voltage measurement; Voltmeters;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.571858
Filename
571858
Link To Document