• DocumentCode
    1457846
  • Title

    Scanning and E.H.T. circuits for wide-angle picture tubes

  • Author

    Jones, Emlyn

  • Volume
    12
  • Issue
    1
  • fYear
    1952
  • fDate
    1/1/1952 12:00:00 AM
  • Firstpage
    23
  • Lastpage
    48
  • Abstract
    One of the major factors which have contributed to the low cost of television receivers, despite the increased cost of production, is the introduction of a.c./d.c. technique. In this country this implies the rather low H.T. rail potential of about 190 V. The demand for bigger and brighter pictures, on the other hand, has led to an increase in the scanning angle of some C.R. tubes, and of the final anode potential. Both these factors imply greater scanning power. The paper is concerned with combined scanning and E.H.T. circuits developed to meet this situation. The operation of energy-recovery scanning circuits is explained, design procedures established and typical circuits are given in detail. Particular attention is paid to the problem of obtaining satisfactory linearity, and a method is described of correcting the horizontal nonlinearity by means of a saturated reactor. Details are also given of an efficient scanning coil wound on a slotted ferrite yoke.
  • Keywords
    cathode-ray tubes; receivers; time bases;
  • fLanguage
    English
  • Journal_Title
    Radio Engineers, Journal of the British Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jbire.1952.0004
  • Filename
    5258630