  • Abstract
    The best life test for fractional-horsepower motors should apply simultaneously or cyclically the major deteriorating factors to the insulation system. These are considered to be heat, voltage, vibration, and humidity. The closer the life-test cycle can match or accelerate possible service conditions, the greater value it will have.
  • Keywords
    Corona; Heating; Humidity; Insulation; Life estimation; Stators; Windings;