DocumentCode
1471749
Title
Ratins of electric equipment under intermittent load
Author
Zucker, Myron
Author_Institution
Mackworth G. Rees, Inc., Detroit, Mich.
Volume
63
Issue
11
fYear
1944
Firstpage
778
Lastpage
783
Abstract
WHEN electric equipment is subjected to intermittent load, as in spot-, flash-, projection-, or gun-welding, it is customary to rate it according to the duty cycle1,2 under which it is to be used. This is good practice as long as we take duty cycle for what it really is: the proportion of time that the equipment is heated — or current “on” time divided by total time. But we may get into trouble by extending this definition to say that temperature rise is proportional to duty cycle — as is commonly done in rating welding equipment for intermittent load.
Keywords
Cooling; Equations; Heating; Mathematical model; Temperature; Temperature measurement; Welding;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1944.6440558
Filename
6440558
Link To Document