DocumentCode
1473542
Title
Evaluating the safety condition of porcelain insulators by the time and frequency characteristics of LC based on artificial pollution tests
Author
Jiang, Xingliang ; Shi, Yan ; Sun, Caixin ; Zhang, Zhijing
Author_Institution
State Key Lab. of Power Transm. Equip. & Syst. Security & New Technol., Chongqing Univ., Chongqing, China
Volume
17
Issue
2
fYear
2010
fDate
4/1/2010 12:00:00 AM
Firstpage
481
Lastpage
489
Abstract
Leakage current (LC) measurement is one of the effective methods for analysis of polluted insulators. But the traditional evaluation methods do not combine well the time-domain with frequency-domain characteristics of LC. In order to evaluate the safety condition of polluted insulators more effectively, an artificial neutral network (ANN) based method was developed in this paper. Firstly, a large number of artificial pollution tests for IEC standard suspension insulators were investigated under different relative humidity (RH) and salt deposit density (SDD). Then, based on the experimental data, the characteristics of LC were analyzed in both time-domain and frequency-domain. The results showed that the peak values of the LC (Ih ) has no relation with SDD when the RH is low ,but when the RH is high, the Ih increases with the increase of SDD; the phase difference (¿) between LC and applied voltage decreases with the increase of RH, the LC becomes inductive when strong local arc occurs; the total harmonic distortion (THD) of LC increases slowly with the increase of RH when the pollution is light, but decreases firstly, then increases with the increase of RH when the pollution is middle or heavy level, the value reaches to minimum when the RH is about 80%. Consequently, Ih, ¿ and THD were proposed as characteristic parameters to evaluate the safety condition of polluted insulators. Finally, an ANN with fuzzy output was developed to evaluate the safety condition of polluted insulators. The input parameters of the ANN were Ih, ¿ and THD, while the output parameters were fuzzified into four fuzzy subsets, the capability of ANN was validated by 8 pairs of testing samples, and the effects of SDD and RH on the performance of insulators were discussed.
Keywords
electrical safety; harmonic distortion; leakage currents; porcelain insulators; IEC standard suspension insulators; THD; artificial neutral network; artificial pollution tests; frequency characteristics; leakage current measurement; polluted insulators; porcelain insulators; relative humidity; safety condition evaluation; salt deposit density; time characteristics; total harmonic distortion; Current measurement; Frequency domain analysis; Insulation; Insulator testing; Leakage current; Pollution measurement; Porcelain; Safety; Time domain analysis; Urban pollution; Leakage current, insulators, salt deposit density (SDD), relative humidity (RH), artificial neutral network (ANN).;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2010.5448104