• DocumentCode
    1475152
  • Title

    Differences in Parameters of Ni-Fe Wound Toroidal Cores Supplied by Industrial Manufacturers

  • Author

    Zurek, Stan

  • Author_Institution
    Megger Instrum. Ltd., Dover, UK
  • Volume
    48
  • Issue
    4
  • fYear
    2012
  • fDate
    4/1/2012 12:00:00 AM
  • Firstpage
    1371
  • Lastpage
    1374
  • Abstract
    The paper presents a practical view on industrially used magnetic cores wound from Ni-Fe tape. The discrepancies between various international suppliers are quite wide, which can have a significant impact on production and in effect on magnetic performance of the final devices.
  • Keywords
    iron alloys; nickel alloys; transformer cores; transformer windings; NiFe; industrial manufacturers; magnetic cores; magnetic performance; wound toroidal cores; Magnetic cores; Magnetic properties; Materials; Permeability; Toroidal magnetic fields; Wounds; Magnetic cores; nickel alloys; production engineering; transformer cores;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2011.2171332
  • Filename
    6172404