  • Abstract
    In the nuclear industry, workers may be exposed to artificial radioactive aerosols. These aerosols are generally composed of particles with a diameter between 0.1 \\mu{\\hbox {m}} and 10 \\mu{\\hbox {m}} . To protect workers in nuclear facilities, monitors continuously measure radioactivity in the air. The main function of the monitor is to provide real-time measurement of activity concentration. Measurement of aerosol activity concentration can be affected by a number of factors specific to the aerosols and the instrument.
  • Keywords
    Aerodynamics; Aerosols; Atmospheric measurements; Ducts; Monitoring; Temperature measurement; Temperature sensors; Aerodispersion; nuclear measurements; radioactive aerosols;