• DocumentCode
    1478536
  • Title

    Moving Average Hybrid Filter to the Enhancing Ultrasound Image Processing

  • Author

    Morales-Mendoza, Luis J. ; Shmaliy, Y.

  • Author_Institution
    Dept. de Electron., Univ. de Guanajuato, Guanajuato, Mexico
  • Volume
    8
  • Issue
    1
  • fYear
    2010
  • fDate
    3/1/2010 12:00:00 AM
  • Firstpage
    9
  • Lastpage
    16
  • Abstract
    In this work, we present a novel technique for ultrasound image processing. The development is carried out trough of the finite impulse response filter (FIR) and the Taylor polynomial approximation. Here, we showed the generic form of the Moving Average Hybrid filter (MAH) to the enhancing ultrasound imaging. Finally, we present any evaluations qualitative and quantitative to the improvement of MAH filter.
  • Keywords
    FIR filters; filtering theory; image enhancement; medical image processing; polynomial approximation; ultrasonic imaging; Taylor polynomial approximation; finite impulse response filter; moving average hybrid filter; ultrasound image processing; Computed tomography; Degradation; Epidermis; Finite impulse response filter; Image processing; Image segmentation; Magnetic resonance imaging; Monitoring; Polynomials; Ultrasonic imaging; FIR Filter; Taylor Polynomial; Ultrasound;
  • fLanguage
    English
  • Journal_Title
    Latin America Transactions, IEEE (Revista IEEE America Latina)
  • Publisher
    ieee
  • ISSN
    1548-0992
  • Type

    jour

  • DOI
    10.1109/TLA.2010.5453940
  • Filename