DocumentCode
1478973
Title
The pollution flashover of ac energized post type insulators
Author
Holtzhausen, J.P. ; Vosloo, W.L.
Author_Institution
Dept. of Electr. & Electron. Eng., Stellenbosch Univ., South Africa
Volume
8
Issue
2
fYear
2001
fDate
4/1/2001 12:00:00 AM
Firstpage
191
Lastpage
194
Abstract
This paper investigates the application of a theoretical model to predict the flashover of practical post type insulators. In particular, the model is applied to two 132 kV designs with different profiles and leakage path lengths. It is found that arc shortening due to inter-shed and inter-rib flashover and arc movement results in a significant deterioration of the pollution performance of the insulator. The theoretical results are confirmed by salt fog tests and field experience
Keywords
flashover; insulator contamination; insulator testing; 132 kV; ac energized post type insulators; arc shortening; inter-rib flashover; inter-shed flashover; leakage path lengths; pollution flashover; salt fog tests; Africa; Flashover; Insulation; Leakage current; Pollution; Shape; Stress; Surface contamination; Surface resistance; Voltage;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.919925
Filename
919925
Link To Document