• DocumentCode
    1482860
  • Title

    Diagnosis and cure of some e.m.c. and interference immunity problems

  • Author

    Fowler, E.P. ; Taylor, J.R.

  • Volume
    49
  • Issue
    2
  • fYear
    1979
  • fDate
    2/1/1979 12:00:00 AM
  • Firstpage
    94
  • Abstract
    Several recent interference investigations are described in some detail. They demonstrate that the technique of injection of radio frequency currents into the earth is effective in locating the weak points in system screens. The use of suitable cables, connectors, filters and remedial techniques can transform what appears to be in some cases a useless system into a trouble-free one. The use of a specially developed pulse generator is shown to be particularly effective when investigating problems in digital systems.
  • Keywords
    electromagnetic compatibility; interference (signal); cables; connectors; digital systems; electromagnetic compatibility; filters; interference immunity; pulse generator; radio frequency currents; signal interference; suppression; system screens;
  • fLanguage
    English
  • Journal_Title
    Radio and Electronic Engineer
  • Publisher
    iet
  • ISSN
    0033-7722
  • Type

    jour

  • DOI
    10.1049/ree.1979.0017
  • Filename
    5269149