DocumentCode
1506185
Title
Patterned Electrodes for Thickness Shear Mode Quartz Resonators to Achieve Uniform Mass Sensitivity Distribution
Author
Richardson, Anthony ; Bhethanabotla, Venkat R. ; Smith, Allan L. ; Josse, Fabien
Author_Institution
Dept. of Chem. & Biomed. Eng., Univ. of South Florida, Tampa, FL, USA
Volume
9
Issue
12
fYear
2009
Firstpage
1772
Lastpage
1777
Abstract
Development of an electrode-modified thickness shear mode (TSM) quartz resonator that is responsive to nanogram mass loadings, while exhibiting a mass sensitivity profile that is independent of material placement on the sensor platform, is the aim of this study. The resulting nanogram balance would greatly enhance the field of mass measurement and become useful in applications such as droplet gravimetry, the study of nonvolatile residue (NVR) contamination in solvents. A ring electrode design predicted by an analytical theory for sensitivity distribution to achieve the desired uniform mass sensitivity distribution is presented in this work. Using a microvalve capable of depositing nanogram droplets of a polymer solution, and a linear stepping stage for radial positioning of these droplets across the sensor platform, measurements of the mass sensitivity distributions were conducted and are presented. The measurements agree well with theory. Further improvements are possible and are identified to achieve better uniformity and to reduce the instability in the resonant frequency of these devices. Additionally, droplet gravimetric results for NVR in methanol droplets using the modified TSM devices are presented, which compare well with determinations made by evaporation of larger volumes of the stock solutions.
Keywords
contamination; crystal resonators; density measurement; electrodes; mass measurement; microvalves; nanosensors; organic compounds; polymer solutions; droplet gravimetry; electrode-modified thickness shear mode quartz resonator; linear stepping stage; mass measurement; mass sensitivity profile; methanol droplets radial positioning; microvalve; nanogram balance; nanogram droplets deposition; nanogram mass loadings; nonvolatile residue contamination; polymer solution; ring electrode design; sensor platform; solvents; uniform mass sensitivity distribution; Biomedical measurements; Biosensors; Contamination; Electrodes; Microvalves; Pollution measurement; Polymers; Resonance; Resonant frequency; Solvents; Droplet gravimetry; mass sensitivity; nanobalance; nonvolatile residue (NVR); thickness shear mode (TSM) quartz resonator;
fLanguage
English
Journal_Title
Sensors Journal, IEEE
Publisher
ieee
ISSN
1530-437X
Type
jour
DOI
10.1109/JSEN.2009.2030658
Filename
5291934
Link To Document