• DocumentCode
    1518821
  • Title

    Virtual PMTs: improving centroid positioning performance near the edges of a gamma camera detector

  • Author

    Vaska, Paul ; Petrillo, Michael J. ; Muehllehner, Gerd

  • Author_Institution
    Med. Dept., Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    48
  • Issue
    3
  • fYear
    2001
  • fDate
    6/1/2001 12:00:00 AM
  • Firstpage
    645
  • Lastpage
    649
  • Abstract
    The radiation detector used in typical gamma cameras and NaI-based positron emission tomography (PET) scanners effectively positions events over most of its crystal area, but the spatial resolution begins to suffer at the edges. One reason is that the measured light distribution is truncated or otherwise asymmetric, and the centroid positioning algorithm no longer optimally weights the photomultiplier tube (PMT) signals in this case. As a result, events less than a certain distance from the edge must be rejected, reducing geometric efficiency and complicating image reconstruction for PET systems with multiple fixed detectors. Short of discarding the centroid algorithm altogether, a computationally simple way to improve the positioning is to define a strip of physically nonexistent, or virtual, PMTs around the actual PMTs and to assign realistic signal values to them event by event based on the signals of nearby real PMTs. If the centroid algorithm now also includes the virtual PMTs, improved spatial resolution is obtained due to better weighting of the PMT signals. With minimal modification to the detector, the virtual PMT method was implemented and tested on an ADAC UGM C-PET detector and found to significantly improve spatial resolution near the detector edges
  • Keywords
    biomedical equipment; cameras; gamma-ray detection; image resolution; photomultipliers; positron emission tomography; NaI; NaI-based positron emission tomography scanners; centroid positioning algorithm; geometric efficiency; image reconstruction complication; measured light distribution; medical diagnostic imaging; medical instrumentation; nuclear medicine; photomultiplier tube signals; spatial resolution; typical gamma cameras; Cameras; Event detection; Image edge detection; Image reconstruction; Photomultipliers; Physics computing; Position measurement; Positron emission tomography; Radiation detectors; Spatial resolution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.940140
  • Filename
    940140