• DocumentCode
    1527621
  • Title

    Cable guns as a plasma source in a plasma opening switch

  • Author

    Kohno, Susumu ; Teramoto, Yusuke ; Lisitsyn, Igor V. ; Katsuki, Sunao ; Akiyama, Hidenori

  • Author_Institution
    Graduate Sch. of Sci. & Technol., Kumamoto Univ., Japan
  • Volume
    27
  • Issue
    3
  • fYear
    1999
  • fDate
    6/1/1999 12:00:00 AM
  • Firstpage
    778
  • Lastpage
    785
  • Abstract
    The characteristics of a plasma generated by cable plasma guns have been studied by a laser interferometer. Cable plasma guns are frequently used as a plasma source in plasma opening switches. In our experiments, the plasma source consists of eight coaxial cable guns mounted on the outer electrode of concentric coaxial electrodes. The reproducibility of the gun in subsequent shots is found to be better than 10%, and the gun-to-gun difference is less than 15%. Assuming a symmetry of eight guns, the contour maps of the electron plasma density are plotted as functions of time. The plasma density becomes maximum near the gun nozzle and near the inner coaxial electrode. The plasma density is low in the area between the coaxial electrodes during the early time of the discharge. At a later time, the plasma fills the space between the two guns more uniformly. Still photographs of the plasma luminosity show a good correspondence with the plasma density plots which were taken 10 μs after the discharge initiation. The plasma gun system is designed for use in a 400-kA inductive voltage adder with the inductive energy storage system
  • Keywords
    electrodes; inductive energy storage; light interferometry; plasma density; plasma diagnostics; plasma guns; plasma production; plasma switches; pulsed power switches; 400 kA; cable plasma guns; coaxial cable guns; concentric coaxial electrodes; contour maps; discharge initiation; early time; electron plasma density; gun nozzle; inductive energy storage system; inductive voltage adder; inner coaxial electrode; laser interferometer; outer electrode; plasma density; plasma density plots; plasma gun system; plasma opening switch; plasma source; pulsed power; reproducibility; Character generation; Coaxial cables; Coaxial components; Electrodes; Guns; Plasma density; Plasma properties; Plasma sources; Reproducibility of results; Switches;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.774683
  • Filename
    774683