Abstract
A method for joint kinematics simulation is described. Kinematics parameters are determined from the relative displacement of marker sets placed on anatomical landmarks of surface models generated from medical imaging contour data. The landmarks are identified manually on fingers in multiple positions. A mathematical algorithm was then used to ascertain the kinematics axes of motion of the fingers. Once these axes are located, they are used as the base of a real time interactive simulation of the finger. The entire simulation was accomplished in a high-resolution graphics environment. A full complement of interactive tools (virtual dials and buttons controlled via mouse) was used to enhance the user interface. The development of the system, the model and the advantages and disadvantages of the method are discussed.
Keywords
biomechanics; computer graphics; digital simulation; kinematics; medical image processing; high-resolution graphics environment; interactive tools; joint kinematics simulation; kinematics parameters; mathematical algorithm; medical imaging data; real time interactive finger simulation; virtual buttons; virtual dials; Biomedical imaging; Computed tomography; Computer graphics; Data visualization; Fingers; Joints; Kinematics; Medical simulation; Surface morphology; User interfaces; Arthrography; Biomechanics; Computer Graphics; Computer Simulation; Finger Joint; Humans; Joints; Models, Biological; Tomography, X-Ray Computed; User-Computer Interface;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.649989
Filename
649989
Link To Document