    Effects of Conductor Counter-Transposition on the Positive-Sequence Impedance and Losses of Cross-Bonded Cables

  • Author

    De León, Francisco ; Márquez-Asensio, Manuel L. ; Álvarez-Cordero, Gabriel

  • Author_Institution
    Polytech. Inst., New York Univ., New York, NY, USA
  • Volume
    26
  • Issue
    3
  • fYear
    2011
  • fDate
    7/1/2011 12:00:00 AM
  • Firstpage
    2060
  • Lastpage
    2063
  • Abstract
    In this letter, we show that contrary to common belief, counter-transposing the conductors when power cables are cross-bonded can increase the positive-sequence resistance by close to 20%. This is very important because the losses of a power cable are determined (for balanced operation) from the Joule loasses caused by the positive-sequence resistance (3R1I12).
  • Keywords
    conductors (electric); losses; power cables; Joule loasses; conductors; counter transposition; cross-bonded cables; positive-sequence resistance; power cables; Cable shielding; Conductors; Equations; Impedance; Power cables; Resistance; Wires; Ampacity; cable parameters; cables; cross-bonding; losses; positive-sequence impedance; resistance;