• DocumentCode
    1556562
  • Title

    Open loop stability characteristics of synchronous drive incorporating high field permanent magnet motor

  • Author

    Mellor, P.H. ; Al-Taee, Majid A. ; Binns, K.J.

  • Author_Institution
    Dept. of Electr. Eng. & Electron., Liverpool Univ., UK
  • Volume
    138
  • Issue
    4
  • fYear
    1991
  • fDate
    7/1/1991 12:00:00 AM
  • Firstpage
    175
  • Lastpage
    184
  • Abstract
    The stability of a buried magnet type of permanent magnet synchronous motor, when operated in a variable speed drive under open loop control, is discussed. The performance of the drive when the permanent magnet machine is constrained to operate at constant power factor is investigated. The stability of the drive is examined using analytical models which describe both the inverter and the permanent magnet machine. The model used for the permanent magnet machine includes the effect of core loss and has variable parameters to account for the changing levels of saturation present in the machine during normal operation. The analysis indicates that the drive can become unstable if the permanent magnet motor is operated at leading power factors in an open loop
  • Keywords
    machine control; permanent magnet motors; synchronous motors; variable speed drives; constant power factor; core loss; inverter; open loop control; permanent magnet synchronous motor; stability; variable speed drive;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • Filename
    79336