Abstract
The stability of a buried magnet type of permanent magnet synchronous motor, when operated in a variable speed drive under open loop control, is discussed. The performance of the drive when the permanent magnet machine is constrained to operate at constant power factor is investigated. The stability of the drive is examined using analytical models which describe both the inverter and the permanent magnet machine. The model used for the permanent magnet machine includes the effect of core loss and has variable parameters to account for the changing levels of saturation present in the machine during normal operation. The analysis indicates that the drive can become unstable if the permanent magnet motor is operated at leading power factors in an open loop
Keywords
machine control; permanent magnet motors; synchronous motors; variable speed drives; constant power factor; core loss; inverter; open loop control; permanent magnet synchronous motor; stability; variable speed drive;