• DocumentCode
    1559612
  • Title

    Novel frequency-domain-based technique to detect stator interturn faults in induction machines using stator-induced voltages after switch-off

  • Author

    Nandi, Subhasis ; Toliyat, Hamid A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Victoria Univ., BC, Canada
  • Volume
    38
  • Issue
    1
  • fYear
    2002
  • Firstpage
    101
  • Lastpage
    109
  • Abstract
    Traditionally, for medium- and high-voltage motors and generators, condition-based monitoring of stator faults is performed by measuring partial discharge activities. For low-voltage machines, negative-sequence impedance or currents are measured for the same. Such diagnostic schemes should be carefully implemented as supply voltage unbalance, manufacturing-related asymmetry, etc., also produce negative-sequence voltages. A few approaches based on motor current signature analysis have already been proposed to detect stator interturn faults. However, little or no physical insight was provided to explain the occurrence of certain harmonics in the line current or the influence of voltage unbalance on these harmonics. Also, in at least one of these papers, a large portion of the stator winding was shorted to emulate the faults. The method proposed in this paper monitors certain rotor-slot-related harmonics at the terminal voltage of the machine, once it is switched off. In the absence of supply voltage, issues such as voltage unbalance, time harmonics do not influence the measurements except as initial conditions, which is a very desirable feature when the machine is fed from an adjustable-speed drive. Satisfactory simulation and experimental results have been obtained with only about 1.5% (5/324) of the total number of turns shorted
  • Keywords
    fault diagnosis; frequency-domain analysis; harmonics; induction motors; machine theory; rotors; stators; adjustable-speed drive; condition-based monitoring; fault diagnosis; frequency-domain-based technique; high-voltage generators; high-voltage motors; induction machines; line current harmonics; rotor-slot-related harmonics; stator faults; stator interturn faults; stator-induced voltages; switch-off; terminal voltage; Condition monitoring; Current measurement; Frequency; Impedance measurement; Manufacturing; Partial discharge measurement; Partial discharges; Performance evaluation; Stators; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/28.980363
  • Filename