• DocumentCode
    15659
  • Title

    Compact Personal Distributed Wearable Exposimeter

  • Author

    Vanveerdeghem, Peter ; Van Torre, Patrick ; Thielens, Arno ; Knockaert, Jos ; Joseph, Wout ; Rogier, Hendrik

  • Author_Institution
    Dept. of Inf. Technol., Ghent Univ., Ghent, Belgium
  • Volume
    15
  • Issue
    8
  • fYear
    2015
  • fDate
    Aug. 2015
  • Firstpage
    4393
  • Lastpage
    4401
  • Abstract
    A compact wearable personal distributed exposimeter (PDE) is proposed, sensing the power density of incident radio frequency (RF) fields on the body of a human. In contrast to current commercial exposimeters, our PDE, being composed of multiple compact personal wearable RF exposimeter sensor modules, minimizes uncertainties caused by the proximity of the body, the specific antenna used, and the exact position of the exposimeter. For unobtrusive deployment inside a jacket, each individual exposimeter sensor module is specifically implemented on the feedplane of a textile patch antenna. The new wearable sensor module´s high-resolution logarithmic detector logs RF signal levels. Next, on-board flash memory records minimum, maximum, and average exposure data over a time span of more than two weeks, at a one-second sample period. Sample-level synchronization of each individual exposimeter sensor module enables combining of measurements collected by different nodes. The system is first calibrated in an anechoic chamber, and then compared with a commercially available single-unit exposimeter. Next, the PDE is validated in realistic conditions, by measuring the average RF power density on a human during a walk in an urban environment and comparing the results to spectrum analyzer measurements with a calibrated antenna.
  • Keywords
    biological effects of fields; electric field measurement; magnetic field measurement; radiofrequency measurement; RF exposimeter sensor; RF signal levels; anechoic chamber; compact exposimeter; distributed exposimeter; high-resolution logarithmic detector; human body; incident radio frequency field power density; on-board flash memory; personal exposimeter; wearable exposimeter; wearable sensor module; Antenna measurements; Antennas; Azimuth; Detectors; Power measurement; Radio frequency; Dosimetry; dosimetry; radio frequency exposure; textile antennas; wearable electronics;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2015.2420583
  • Filename
    7080863