• DocumentCode
    158814
  • Title

    Methods of triggering for the cold cathode thyratrons with auxiliary glow discharge in trigger system

  • Author

    Landl, N.V. ; Korolev, Y.D. ; Frants, O.B. ; Shemyakin, I.A. ; Geyman, V.G.

  • Author_Institution
    Inst. of High Current Electron., Tomsk, Russia
  • fYear
    2014
  • fDate
    Sept. 28 2014-Oct. 3 2014
  • Firstpage
    361
  • Lastpage
    364
  • Abstract
    The paper describes the schematic design and principle of operation for the ceramic-metal sealed-off pseudospark switches with the auxiliary glow discharge in the trigger unit. The switches are produced commercially by the Pulsed Technology Ltd., Ryazan, Russia [http://www.pulsetech.ru/index.htm] and are known as the switches of TPI-series whose anode voltage ranges from several to 50 k V. Proceeding from the switch design and the methods of triggering, the TPI switches can be referred to as the cold cathode thyratrons. Triggering methods for the electric circuits corresponding to grounded grid thyratron and to classical thyratron with cold cathode are considered.
  • Keywords
    cold-cathode tubes; glow discharges; thyratrons; anode voltage; auxiliary glow discharge; ceramic-metal sealed-off pseudospark switches; cold cathode thyratrons; grounded grid thyratron; switch design; triggering; Anodes; Cathodes; Cavity resonators; Discharges (electric); Electron tubes; Rectifiers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Discharges and Electrical Insulation in Vacuum (ISDEIV), 2014 International Symposium on
  • Conference_Location
    Mumbai
  • Print_ISBN
    978-1-4799-6750-6
  • Type

    conf

  • DOI
    10.1109/DEIV.2014.6961694
  • Filename
    6961694