• DocumentCode
    1588603
  • Title

    Magnetic core losses measurement instrumentations and a dynamic hysteresis loss model

  • Author

    Zhang, Yu ; Alatawneh, Natheer ; Cheng, Ming C. ; Pillay, Pragasen

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Clarkson Univ., Potsdam, NY, USA
  • fYear
    2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Three typical types of magnetic lamination core loss measurement methods, the toroid tester, the standard Epstein frame and a single sheet tester, are first reviewed. Results of four types of testing (previous three plus a new Epstein frame for high flux density and frequency) are presented and compared. Comparisons among the measurements of different frames show discrepancies in the loss results. A general dynamic hysteresis core loss model is also presented. The model can calculate core losses based on the input parameters obtained from experimental measurements at only one single frequency in a thin lamination. The developed dynamic hysteresis model is simple and efficient, and has been shown to be very accurate compared with experiments.
  • Keywords
    eddy current losses; instruments; laminations; loss measurement; magnetic cores; magnetic field measurement; dynamic hysteresis loss model; general dynamic hysteresis core loss model; magnetic core losses measurement instrumentations; magnetic lamination; thin lamination; Core loss; Frequency; Instruments; Lamination; Loss measurement; Magnetic cores; Magnetic flux; Magnetic hysteresis; Magnetic losses; Testing; Core losses; Epstein frame; finite element analysis; hysteresis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Power & Energy Conference (EPEC), 2009 IEEE
  • Conference_Location
    Montreal, QC
  • Print_ISBN
    978-1-4244-4508-0
  • Electronic_ISBN
    978-1-4244-4509-7
  • Type

    conf

  • DOI
    10.1109/EPEC.2009.5420918
  • Filename
    5420918