Abstract
Three typical types of magnetic lamination core loss measurement methods, the toroid tester, the standard Epstein frame and a single sheet tester, are first reviewed. Results of four types of testing (previous three plus a new Epstein frame for high flux density and frequency) are presented and compared. Comparisons among the measurements of different frames show discrepancies in the loss results. A general dynamic hysteresis core loss model is also presented. The model can calculate core losses based on the input parameters obtained from experimental measurements at only one single frequency in a thin lamination. The developed dynamic hysteresis model is simple and efficient, and has been shown to be very accurate compared with experiments.
Keywords
eddy current losses; instruments; laminations; loss measurement; magnetic cores; magnetic field measurement; dynamic hysteresis loss model; general dynamic hysteresis core loss model; magnetic core losses measurement instrumentations; magnetic lamination; thin lamination; Core loss; Frequency; Instruments; Lamination; Loss measurement; Magnetic cores; Magnetic flux; Magnetic hysteresis; Magnetic losses; Testing; Core losses; Epstein frame; finite element analysis; hysteresis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Power & Energy Conference (EPEC), 2009 IEEE
Conference_Location
Montreal, QC
Print_ISBN
978-1-4244-4508-0
Electronic_ISBN
978-1-4244-4509-7
Type
conf
DOI
10.1109/EPEC.2009.5420918
Filename
5420918
Link To Document