DocumentCode
1592339
Title
Two level full bridge inverter with soft switching without stresses
Author
Rodrigues, E.A. ; Coelho, E.A.A. ; de Freitas, L.C. ; Vieira, J.B., Jr. ; Farias, E.V.J.
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
1131
Abstract
This paper presents a two-level single phase full-bridge inverter which has four main switches operating at high frequency. In order to reduce the commutation losses and EMI content, each switch uses a stressless commutation cell. The proposed topology works in two levels with sinusoidal PWM modulation. The operating principles, relevant equations and test results are presented. The obtained results validate the proposed inverter
Keywords
DC-AC power convertors; PWM invertors; bridge circuits; commutation; losses; switching circuits; EMI content reduction; commutation losses reduction; equations; high-frequency switching; operating principles; sinusoidal PWM modulation; soft switching; stressless commutation cell; test results; two-level single phase full-bridge inverter; Bridges; Electromagnetic interference; Equations; Frequency; Pulse width modulation; Pulse width modulation inverters; Stress; Switches; Testing; Topology;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2001. PESC. 2001 IEEE 32nd Annual
Conference_Location
Vancouver, BC
ISSN
0275-9306
Print_ISBN
0-7803-7067-8
Type
conf
DOI
10.1109/PESC.2001.954271
Filename
954271
Link To Document