• DocumentCode
    1593216
  • Title

    Novel Failure Isolation Techniques for Circuits Sensitive to Microprobe

  • Author

    Fan, DiWei ; Wu, Miao ; Yu, Joe ; Wang, Winter ; Wu, Chunlei ; Li, Jinglong ; Tian, Li

  • Author_Institution
    Freescale Semicond. (China) Ltd., Tianjin, China
  • fYear
    2012
  • Firstpage
    401
  • Lastpage
    404
  • Abstract
    Voltage measurement of test pad directly by microprobe is typical technique in circuit isolation stage of failure analysis. But in some special circuits which are sensitive to microprobe, the voltage of some test pads will change when microprobe needle touches the test pads. Hence it is necessary to develop new measurement skills to confirm test pad status instead of measuring voltage directly. This paper introduces several novel measurement methods to solve this issue and demonstrates these skills with real cases.
  • Keywords
    failure analysis; integrated circuit testing; probes; voltage measurement; circuit isolation stage; failure analysis; failure isolation; microprobe needle; sensitive circuit; test pad; voltage measurement; Current measurement; Electrical resistance measurement; Fluid flow measurement; Needles; Resistance; Semiconductor device measurement; Voltage measurement; Failure analysis; microprobe; sensitive circuit;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent System Design and Engineering Application (ISDEA), 2012 Second International Conference on
  • Conference_Location
    Sanya, Hainan
  • Print_ISBN
    978-1-4577-2120-5
  • Type

    conf

  • DOI
    10.1109/ISdea.2012.399
  • Filename
    6173231