DocumentCode
1594245
Title
Factor affecting the pulse width of capillary discharge soft x-ray laser
Author
Niimi, G. ; Hayashi, Y. ; Okino, A. ; Watanabe, M. ; Hotta, E.
Author_Institution
Dept. of Energy Sci., Tokyo Inst. of Technol., Yokohama, Japan
Volume
1
fYear
2001
Firstpage
746
Abstract
Capillary discharge experiments were carried out to get a lasing of Ne-like Ar line (J=0-1, /spl lambda/=46.9 nm) with two devices. At optimum condition with one device, gain-length product gl of 8.4 (g=0.7 cm/sup -1/), laser energy of 300 nJ and FWHM of 2.5 ns were obtained. With the other device, laser energy of 135 nJ and FWHM of 0.6 ns were obtained. Comparison with two devices, the pulse widths of laser may depend on theirs dl/dt.
Keywords
X-ray lasers; argon; discharges (electric); ion lasers; isoelectronic series; laser transitions; 0.6 ns; 135 nJ; 2.5 ns; 300 nJ; 46.9 nm; Ar/sup +/; Ar/sup +/ soft X-ray ion lasers; Ne-like Ar line; capillary discharge soft x-ray laser; gain-length product; laser energy; optimum condition; pulse width; Argon; Cathodes; Diodes; Laser theory; Optical pulses; Plasma x-ray sources; Space vector pulse width modulation; X-ray detection; X-ray lasers; X-ray scattering;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulsed Power Plasma Science, 2001. PPPS-2001. Digest of Technical Papers
Conference_Location
Las Vegas, NV, USA
Print_ISBN
0-7803-7120-8
Type
conf
DOI
10.1109/PPPS.2001.1002204
Filename
1002204