    A interturn fault protection method of HV shunt reactors based on unbalanced parameter detection

  • Author

    Mao Peng ; Qin Hong ; Xiangning, Lin ; Shuai Lingling ; Qixin, Xiong

  • Author_Institution
    Jiangxi Electr. Power Co., Nanchang, China
  • fYear
    2010
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    An interturn fault protection method of the HV shunt reactor is put forward in this paper, which is based on the unbalanced parameter detection. This method is established on the basis of the time-domain parameter model, and uses the electrical quantities at two terminals of the HV reactor to calculate the electrical parameters of each phase by mean of least squares algorithm. Suppose that the interturn short-circuit faults of the HV phase-separated shunt reactors impossibly occur at three phases at the same time, we could identify whether the interturn short-circuit fault of the HV reactor occurs by designing the comprehensive detection criterion which could reflect three-phase unbalanced parameters and parameter mutation. The interturn protection of HV reactors could avoid the impact from power swings and frequency deviation. This method is based on the measurement and the comparison of per-phase equivalent inductance parameters of the reactor. The setting of the protection is simple and convenient to implement. Furthermore, the protection has high sensitivity. Because this interturn protection detects the variation of per-phase inductance parameters, it could avoid the influence from the system operating mode and the fault while those based on the principle of sequence components cannot. It is also adaptive to the installation location of the voltage transformer (PT), and could be easily applied to HV reactors of both transmission lines and busbars.
  • Keywords
    fault location; high-voltage techniques; least squares approximations; potential transformers; power system parameter estimation; power transformer protection; reactors (electric); time-domain analysis; HV phase-separated shunt reactor; frequency deviation; interturn fault protection method; interturn short-circuit fault; least squares algorithm; power swing; time-domain parameter model; unbalanced parameter detection; voltage transformer; Inductance; Inductors; TV; Least square algorithm; parameter detection; shunt reactors; the interturn protection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power System Technology (POWERCON), 2010 International Conference on
  • Conference_Location
    Hangzhou
  • Print_ISBN
    978-1-4244-5938-4
  • Type

    conf

  • DOI
    10.1109/POWERCON.2010.5666110
  • Filename
    5666110