DocumentCode
1619020
Title
Equipment ESD capability measurements
Author
Steinman, Arnold
Author_Institution
Electron. Workshop, Dangelmayer Assoc., Berkeley, CA, USA
fYear
2013
Firstpage
1
Lastpage
8
Abstract
There are no standards for establishing equipment capability to handle devices of known ESD sensitivity. Prior papers established that voltages on components correlate to CDM test voltages. But current in the discharge damages devices, not the voltage. This paper describes a procedure and test fixture for discharge current measurements in equipment to compare with discharges of CDM testing.
Keywords
electric current measurement; electronic equipment testing; electrostatic discharge; CDM testing; ESD sensitivity; discharge current measurements; discharge damages devices; electrostatic discharge; equipment capability measurements; test fixture; Current measurement; Discharges (electric); Electrical resistance measurement; Electrostatic discharges; Fixtures; Standards; Voltage measurement;
fLanguage