• DocumentCode
    1619813
  • Title

    Measurement of low-pressure gas flow rate by the active sound detection method

  • Author

    Kikuchi, Masaharu ; TANISAWA, Shigeru ; Hirose, Haruo

  • Author_Institution
    Nippon Inst. of Technol., Saitama, Japan
  • Volume
    1
  • fYear
    2004
  • Firstpage
    471
  • Abstract
    Ultrasonic wave signals are generated by equipping a small sound-radiator in the sub-pipe line that separates from the main pipeline. Present study is an attempt to measure the flow rate based on the sound pressure level of the signals. Average flow velocities and average received voltages were approximately proportional. As an advantage, fluid temperature change is difficult to influence.
  • Keywords
    acoustic intensity measurement; acoustic radiators; flowmeters; pipelines; pressure measurement; ultrasonic waves; active sound detection method; average flow velocities; average received voltages; fluid temperature; low-pressure gas flow rate measurement; sound pressure level; sound-radiator; ultrasonic flowmeter; ultrasonic wave signals;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE 2004 Annual Conference
  • Conference_Location
    Sapporo
  • Print_ISBN
    4-907764-22-7
  • Type

    conf

  • Filename
    1491447