• DocumentCode
    1622231
  • Title

    FBP reconstruction of cone-beam data acquired with a vertex path containing a circle

  • Author

    Noo, Férdéric ; Defrise, Michel ; Clack, Rolf

  • Author_Institution
    Liege Univ., Belgium
  • Volume
    3
  • fYear
    1996
  • Firstpage
    1698
  • Abstract
    The paper presents a reconstruction algorithm for cone-beam (CB) data acquired with a vertex path which consists of a circle and of a complementary path such that Tuy´s (1983) data sufficiency condition is fulfilled. The algorithm is based on the CB filtered-backprojection method of Defrise and Clack (1994), with an appropriate handling of redundancy to reduce the processing of the circle data to a stationary 2D filtering. The method is similar to a previous algorithm of Kudo and Saito (1994), and it also admits reconstruction from truncated data. However, the use of a 2D filter for the circle data instead of a 1D ramp filter avoids singularities in the filtered projections
  • Keywords
    computerised tomography; filtering theory; image reconstruction; medical image processing; CB filtered-backprojection method; FBP reconstruction; circle; cone-beam data; data sufficiency condition; filtered projections; reconstruction algorithm; redundancy; stationary 2D filtering; truncated data reconstruction; vertex path; Algorithm design and analysis; Detectors; Filtering algorithms; Filters; Image reconstruction; Joining processes; Reconstruction algorithms; Tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.587956
  • Filename
    587956