    Prediction of harmonic power losses in fuses located in DC-link circuit of an inverter

  • Author

    Iov, F. ; Blaabjerg, Frede ; Ries, K.

  • Author_Institution
    Inst. of Energy Technol., Aalborg Univ., Denmark
  • Volume
    4
  • fYear
    2001
  • Firstpage
    2505
  • Abstract
    Fuses may in the future enter into the DC-link of voltage source converters and the harmonic power losses prediction in fuses are very important for manufacturers in order to predict the life-time and protection level of the converter. The DC-link current has a high harmonic content for an inverter that uses any kind of space vector modulation strategy. The aim of this paper is to find a useful approximation for the AC resistance of a fuse and to predict the harmonic power losses into it when it is fed from an inverter.
  • Keywords
    DC-AC power convertors; electric fuses; harmonic distortion; invertors; losses; power conversion harmonics; protection; AC resistance approximation; harmonic power losses prediction; high harmonic content; invertor DC-link circuit fuses; lifetime prediction; protection level prediction; space vector modulation strategy; voltage source converters; Capacitors; Circuits; Fuses; Insulated gate bipolar transistors; Inverters; Manufacturing; Power electronics; Power system harmonics; Protection; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Conference, 2001. Thirty-Sixth IAS Annual Meeting. Conference Record of the 2001 IEEE
  • Conference_Location
    Chicago, IL, USA
  • ISSN
    0197-2618
  • Print_ISBN
    0-7803-7114-3
  • Type

    conf

  • DOI
    10.1109/IAS.2001.955973
  • Filename