DocumentCode
1667616
Title
Magnetic damping effects in fusion reactor first wall
Author
Yoshida, Y. ; Miya, K.
Author_Institution
Nuclear Engineering Research Laboratory, University of Tokyo
fYear
1992
Abstract
Summary from only given, as follows. This paper describes numerical simulation of magneto-structural coupled vibration of a fusion reactor first wall. A numerical code was developed based on FEM. Current vector potential method based on thin plate approximation was applied to the electromagnetic field calculation including electromotive force by velocity. The code was applied to the ITER first wall. Numerical results show that flexible thin structure is preferably applicable to the first wall and other structural components.
Keywords
Damping; Fusion reactors;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Field Computation, 1992. Digest of the Fifth Biennial IEEE Conference on
Conference_Location
Claremont, CA, USA
Type
conf
DOI
10.1109/CEFC.1992.720729
Filename
720729